iTEMP TMT82 Operating options
Endress+Hauser 25
6.3 Measured value display and operating elements
6.3.1 Display elements
Head transmitter
A0008549
14 Optional LC display for head transmitter
Item No. Function Description
1 Displays the TAG TAG, 32 characters long.
2 'Communication' symbol The communication symbol appears when read and write-accessing via
the fieldbus protocol.
3 Unit display Unit display for the measured value displayed.
4 Measured value display Displays the current measured value.
5 Value/channel display S1,
S2, DT, PV, I, %
e.g. S1 for a measured value from channel 1 or DT for the device
temperature
6 'Configuration locked'
symbol
The 'configuration locked' symbol appears when configuration is locked
via the hardware.
7 Status signals
Symbols Meaning
Error message "Failure detected"
An operating error has occurred. The measured value is no longer valid.
The display alternates between the error message and "- - - -" (no valid
measured value present), see "Diagnostics events" → 39 section.
"Service mode"
The device is in service mode (e.g. during a simulation).
"Out of specification"
The device is being operated outside its technical specifications (e.g.
during warm-up or cleaning processes).
"Maintenance required"
Maintenance is required. The measured value is still valid.
The display alternates between the measured value and the status
message.
DIN rail transmitter
The DIN rail transmitter version does not have an interface to the LC display and
therefore does not have a local display either.