Levelflex FMP55 HART Operating menu
Endress+Hauser 149
"Probe length correction" wizard
The Probe length correction wizard is only available when operating via the local
display. When operating via an operating tool, all parameters concerning the probe
length correction are located directly in the Probe settings submenu (→  147).
Navigation  Setup → Advanced setup → Probe settings → Prob.length corr
Confirm probe length
Navigation Setup → Advanced setup → Probe settings → Prob.length corr → Confirm length
Description →  148
Present probe length
Navigation  Setup → Advanced setup → Probe settings → Prob.length corr → Pres. length
Description →  147