8.4 Sampler
8.4.1 Sampler (Input, FC: 04)
Register
Data Type
Bytes
R/W
Unit
Description
1500
OCTETSTRING16
16
R
None
Program name
1508
UNSIGNED8
1
R
None
Current bottle position
1509
UNSIGNED8
1
R
None
Mode of sampling
Selection:
0: Time paced CTCV (default)
1: Flow paced VTCV
2: Time/flow paced CTVV
3: Single sample
4: Sampling table
5: External signal
6: Manual
7: Fieldbus Input
1510
DATETIME
8
R
None
Date and time of next sampling
Factory default: 2000-01-01T00:00:00
1514
FLOAT
4
R
None
Dosing volume of last sample taking
1516
OCTETSTRING16
16
R
None
Name of current active program
Factory default: E_TextID_Program
1524
UNSIGNED8
1
R
None
Program state
Selection:
0: Inactive (default)
1: Active
2: Pause
3: Waiting for pause
1525
UNSIGNED8
1
R
None
Bottle assignement
Selection:
0: 1x - PE Direct distribution (default)
1: 2x - PE Direct distribution
2: 4x - PE Direct distribution
3: 4x - Glass Direct distribution
4: 12x - PE Direct distribution
5: 12x - PE/Glass Plate distribution
6: 24x - PE Direct distribution
7: 24x - PE/Glass Plate distribution
8: 6x+1x - PE/Glass Plate distribution
9: 6x+2x - PE+PE Plate distribution
10: 6x+2x - PE+Glass Plate distribution
11: 12x+1x - PE/Glass Plate distribution
12: 12x+2x - PE+PE Plate distribution
13: 12x+2x - PE+Glass Plate distribution
14: 12x+6x - PE Direct distribution
15: 12x+6x - PE/Glass Plate distribution
16: 4x - Glass Schott GLS80 Direct distribution
1526
FLOAT
4
R
CubicMeter
Bottle volume
Factory default: 0.03
1528
FLOAT
4
R
CubicMeter
Bottle volume of the right bottle box
1530
FLOAT
4
R
CubicMeter
Liquid level of selected bottle
1532
UNSIGNED8
1
R
None
Sampling mode
Selection:
0: Peristaltic (default)
1: Vacuum
2: Inline
1533
FLOAT
4
R
CubicMeter
Dosing volume of vacuum- or inline-sampler
Factory default: 0.0002
1535
DATETIME
8
R
None
Start time of last sampling
Factory default: 1970-01-01T00:00:00
1539
UNSIGNED32
4
R
None
Number of distribution lever calibrations
1541
DATETIME
8
R
None
Time stamp of last distribution lever calibration
Factory default: 1970-01-01T00:00:00

Table of Contents