Loading...
Micropilot FMR62
Endress+Hauser 43
FMR62, integrated antenna PEEK, 200 °C (392 °F)
p
-40
(-40)
-20
(-4)
+200
(+392)
0
(+32)
T
p
[°C]
([°F])
1
2
[bar] ([psi])
20 (290)
-1 (-14.5)
0 (0)
A0032183
 20 FMR62: Permitted range for process temperature and process pressure, integrated antenna, PEEK (feature
070: GE, GF), 200 °C (392 °F)
1 Feature 90, seal: A6, FKM Viton GLT
2 Feature 90, seal: C2, FFKM Kalrez
FMR62, integrated antenna, PEEK, feature 070: GE, GF
Feature 100 "Process connection" Feature 90
"Seal"
Process temperature
range
Process pressure range
Thread
GDJ: ISO228 G3/4, 316L
GGJ: ISO228 G1-1/2, 316L
RDJ: ANSI MNPT3/4, 316L
RGJ: ANSI MNPT1-1/2, 316L
A6, FKM Viton
GLT
–40 to +200 °C
(–40 to +392 °F) p
rel
=
–1 to 20 bar
(–14.5 to 290 psi)
1)
C2, FFKM
Kalrez
–20 to +200 °C
(–4 to +392 °F)
1) The pressure range may be reduced further if the device has a CRN approval
FMR62, Tri-Clamp 2" process connection
p
-40
(-40)
+150
(+302)
+200
(+392)
0
(+32)
T
p
[°C]
([°F])
1
2
[bar] ([psi])
16 (232)
-1 (-14.5)
0 (0)
A0032618
 21 FMR62: Permitted range for process temperature and process pressure, Tri-Clamp 2" process connection
1 Feature 90, seal, F5
2 Feature 90, seal, F6

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR62