PROline Promass 80 QUICK SETUP “Commissioning”
Endress+Hauser 3
QUICK SETUP “Commissioning”
!
Note:
More detailed information on running Quick Setup menus, especially for devices without
a local display, can be found on Page 50 ff.
Information on the points numbered in the Quick Setup can be found on the following
page.
+
+
+
E
E
Esc
E
-
+
Ye s
Ye s
Ye s
No
No
No
Mass flow
Current output 1
Volume flow Density
Frequency/Pulse output
Selection System Units
Selection output type
Configuration another unit ?
Configuration another output ?
Automatically configuration display ?
Temperature Quit
Quit
Unit
Mass flow
Assign
Current
Current span
Value
0/4 mA
Value
20 mA
Time constant
Time constant
Failsafe mode
Failsafe mode
Failsafe mode
Assign
Frequency
End value
frequency
Value
F Low
Value
F High
Output signal
Assign
Pulse
Pulse value
Pulse width
Output signal
Unit
flowVolume
Unit
Density
Operation mode
Unit
Temperature
Measuring
Mode
Unit
Totalizer
Unit
Totalizer
Frequency
Pulse
Automatically
parameterization
of the display
Language
Pre-setting
Quick Setup
HOME-POSITION
Quick Setup
Commission
Assign
Current
Current span
Value
0/4 mA
Value
20 mA
Time constant
Failsafe mode
Current output 2
Corr. Vol. flow
Unit
Corr. Vol. flow
Unit
Ref. Density
Fix
Ref. Density