10 Functions at a Glance
SYSTEM UNITS
FLOW RATE UNIT
(p. 47)
dm
3
/s dm
3
/min dm
3
/h
m
3
/s m
3
/min
m
3
/h
l/s l/min l/h
hl/min hl/h
gal/min gal/hr gal/day
gpm gph gpd mgd –
bbl/min bbl/hr bbl/day
cfs (cubic feet per second)
cc/min
Your setting: .............................................
VOLUME UNIT
(p. 47)
dm
3
m
3
l hl gal bbl
10
3
gal ft
3
Your setting: .............................................
GALLONS /
BARREL
(p. 48)
US: 31.0 gal/bbl
US: 31.5 gal/bbl
US: 42.0 gal/bbl
US: 55.0 gal/bbl
Imp: 36.0 gal/bbl
Imp: 42.0 gal/bbl
Your setting: ............................................
NOM. DIAM. UNIT
(p. 48)
mm
inch
Your setting: ............................................
CURRENT OUTPUT
FULL SCALE 1
(p. 49)
5-digit floating point (e.g. 250.00 m
3
/h)
Factory setting:
dependent
on diameter
Your setting: ............................................
DUAL RANGE
MODE
(p. 50)
OFF
(only full scale value 1 active)
ON (full scale value 1 or 2 active)
Your setting: ............................................
FULL SCALE 2
(p. 51)
5-digit floating point (e.g. 3600.0 m
3
/h)
Factory setting:
dependent
on diameter
Your setting: ............................................
ACTIVE RANGE
(p. 51)
Display:
FULL SCALE 1
or FULL SCALE 2
TIME CONSTANT
(p. 51)
Floating point: 0.01...100 s
Factory setting:
1.0 s
Your setting: ............................................
CURRENT SPAN
(p. 51)
0–20 mA
4–20 mA
0–20 mA (25 mA)
4–20 mA (25 mA)
Your setting: ............................................
CURRENT OUTPUT (continued)
FAILSAFE MODE
(p. 51)
MIN. CURRENT
Signal is set to the following value:
0 mA (with 0–20 mA)
2 mA (with 4–20 mA)
MAX. CURRENT
Signal is set to the following value:
22 mA (with 4–20 mA)
25 mA (with 0/4–20 mA [25 mA])
HOLD VALUE
Last valid measured value is held.
ACTUAL VALUE
Normal measured value output despite
fault.
Your setting: ............................................
SIMULATION
CURR.
(p. 52)
With “0–20 mA”:
OFF
0 mA 10 mA 20 mA –
22 mA
With “0–20 mA (25 mA)”:
OFF
0 mA 10 mA – 20 mA – 25 mA
With “4–20 mA”:
OFF
2 mA 4 mA – 12 mA
20 mA – 22 mA
With “4–20 mA (25 mA)”:
OFF
2 mA 4 mA – 12 mA –
20 mA – 25 mA
Your setting: ............................................
NOMINAL
CURRENT
(p. 52)
Displayed value: 0.00...25.00 mA
PULSE / FREQ. OUTPUT
OPERATION
MODE
(p. 53)
PULSE
FREQUENCY
Your setting: ............................................
PULSE VALUE
(p. 53)
5-digit floating point (e.g. 240.00 m
3
/p)
Factory setting:
dependent
on diameter
Your setting: ............................................
PULSE WIDTH
(p. 53)
3-digit fixed point: 0.05...2.00 s
Factory setting:
2.00 s
Your setting: ............................................
FULL SCALE
FREQ.
(p. 54)
max. 5-digit number: 2...10000 Hz
Factory setting:
10000 Hz
Your setting: ............................................
FULL SCALE
FLOW
(p. 55)
5-digit floating point: e.g. 7.2500 m
3
/h
Your setting: ............................................
Promag 33 10 Functions at a Glance
Endress+Hauser 117