In case of breakdown, press the control unit
switch on the left part of the rocker to the
rst position (switch position 0). The unit is
now completely switched off.
The control unit switch (Switch-
off)
The control unit switch can be found on the
top end of the unit. Using this switch, you
can isolate the electronics from the mains
supply in case of a breakdown.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).
C o n t r o l u n i t
switch
= unit swit-
ched on
= unit swit-
ched off
= light swit-
ched on
Switching over the heating time limitation for commercial use or wee-
kly timer
Attention! Completely disconnect the control unit from the electrical circuit!
As a standard, the control unit is supplied with a heating time limitation of max. 6 hours.
To c hang e o ver t o m ax. 1 2 hou r s, t h e re i s a j umpe r s ocke t o n the bot -
tom board. This is plugged in the factory with the 6h marking. By changing to
12 or 24h , the heating time can be set to max. 12 hours, max. 24 hours or
(
8
) innitely. If the jumper is removed, the heating time is max. 6 hours. By plugging the
jumper to “Res” , the weekly timer is activated.
The maximum heating time for private use is 6 hours. Resetting to 12 or more
hours is permissible only for supervised (commercial) operation.
- : - -
= Jumper 24h
P2 =
8
F1
F2
X3
X5a
X2
Jumper
Display
X5
X1
X6
X4
PE
L1 L2 L3 N
N
N
U
V
W
WB
S1
FAN
LIGHT
WM
L N L N
P+
TEMP.-SENSOR
Nr. 2
Nr. 1
TEMP.-
LIMITER
H-SENSOR
Ub
E G
Res
24h
12h
6h
500 mA T
500 mA T