Technical data
Nominal voltage: 400 V 3 N AC 50 Hz
Switching load: max. 9 kW Ohm resistive load (AC1 - mode)
device can be extended by connecting powered control units
up to 36 kW
Heating time limit: 6 hr, 12 hr or no heating time limit
Display: Jumbo backlit LCD
Protection class: IPx4 in line with EN 60529 splashed water resistant
Normal range for sauna: 30 to 110°C
Sensor system: KTY sensor with safety temperature limiter 142°C
Control characteristic: digital two-point regulation
Fan output: min. 25 W max.100 W (only fan excluding capacitor)
Light: min. 25 W max.100 W Only ohm resistive load, we recommend
to use special bulbs like baking oven bulbs. Other lamps have to
use with the optional control modules.).
Coloured light (optional): max. 100 W per colour
Colour on-time: 1 - 10 min
Colour order: red - red/yellow - yellow - yellow/green - green - green/blue - blue
- blue/red
Error display: via warning triangle (ashing) and error code on LCD
Ambient temperatures: -10°C to +35°C
Storage temperatures: -20°C to +60°C
Fuse protection on the light and the ventilation can
be a maximum of 1A delay action. There is a danger
of re if greater fuse protection is used!

Table of Contents

Other manuals for EOS EMOTEC DC 9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EOS EMOTEC DC 9000 and is the answer not in the manual?

EOS EMOTEC DC 9000 Specifications

General IconGeneral
BrandEOS
ModelEMOTEC DC 9000
CategoryControl Unit
LanguageEnglish

Related product manuals