EN 61000-6-3 (2007), Amd. A1 (2011)
Electromagnetic compatibility-generic emission standard
part6-3: residential, commercial and light industry
Radiated disturbance emission
test
Test method EN 55016-2-3
Frequency
(MHz)
Limit value
(dBmV/m)
30 - 1000 30/37 (QP)
1000 - 6000
70/74 (QP)
Conducted disturbance at main
ports emission test
Test method EN 55016-2-1
Frequency
(MHz)
Limit value (dBmV)
0,15 - 30 66/56/60 (QP)
0,15 - 30 56/46/50 (AVE)
EN 61000-6-2 (2005)
Electromagnetic compatibility-generic immunity standard
part6-2: industrial environment
Conducted radio-frequency
common mode immunity test
Test method EN 61000-4-6
Performance criterion A
Specification Port Test
level
Frequency range
0,150-80 MHz,
Modulation
AM80% 1 kHz,
Dwell time 1 s
DC
input
port
10
V
RMS
Signal
ports
10
V
RMS
Radiated radio-frequency
electromagnetic field immunity test
Test method EN 61000-4-3
Performance criterion A
Specification
Range
(MHz)
Test
level
Modulation
AM 80% 1 kHz,
Dwell time 1 s
80-1000 10 V/m
1400-
2000
3 V/m
2000-
2700
1 V/m
Modulation
1000-
1400
3 V/m

Table of Contents