11. Reference information
RX4111CE Jump to Top / Bottom
ETM62E-02 Seiko Epson Corporation 16
11.1. Reference Data
(1)Example of frequency and temperature characteristics
[Finding the frequency stability]
1.Frequency and temperature characteristics can be
approximated using the following equations.
fT : Frequency deviation in any temperature
C
2
] : Coefficient of secondary temperature
(0.0350.005)10
6
/
C] : Ultimate temperature(+255
C] : Any temperature
2.To determine overall clock accuracy, add the
frequency precision and voltage characteristics.
f/f : Clock accuracy (stable frequency)
in any temperature and voltage.
f/fo : Frequency precision
fT : Frequency deviation in any temperature.
fV : Frequency deviation in any voltage.
3.How to find the date difference
Date Difference =
86400 (Sec)
For example:
f/f = 11.57410
-6
is an error of
approximately 1 second/day.
Figure 18 Frequency vs Temperature characteristics
"Link"