14. How to use
RX4111CE Jump to Top / Bottom
ETM62E-02 Seiko Epson Corporation 46
14.8.4. Time Stamp Record Register.
When an event is detected, the following data is recorded .
Multiple access time stamp data is available. Refer to Figure 33.
Figure 36 Time stamp recording registers
Table 55 Time Stamp Record Register
Bank2
Address
Function
Time stamp data
0h
Time Stamp 1/1024S
256Hz,512Hz.
1h
Time Stamp 1/128S
1Hz~256Hz
2h
Time Stamp SEC
Seconds
3h
Time Stamp MIN
Minutes
4h
Time Stamp HOUR
Hours
5h
Time Stamp WEEK
Day
6h
Time Stamp DAY
Date
7h
Time Stamp MONTH
Month
8h
Time Stamp YEAR
Years
9h
Status Stamp
RTC Internal status (VDET, XST)
Status stamp register
Table 56 Status Stamp
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Bank2 9h
Status Stamp
z
z
VDET
z
XST
z