SC-S30600 Series Revision B
TROUBLE SHOOTING Remedies for Service Call Error 45
Confidential
1F80 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1F81 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1F82 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1F83 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1F84 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1F85 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1FB9 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1FC0 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
1FC1 CSIC error
CSIC control error
---
1. Replace the IC Holder. (Page 143)
2. Replace the Main Board. (Page 107)
2000 NVRAM error
NVRAM erase or write error has occurred.
---
Replace the Main Board. (Page 107)
2002 SDRAM error
Writing to the SDRAM was attempted, but nothing
could be written to it.
--- Replace the Main Board. (Page 107)
2003
FLASH BOOT
checksum error
Installing the firmware has failed.
The Flash ROM is out of order.
---
1. Re-install the firmware. (Page 227)
1. Replace the Main Board. (Page 107)
200A F/W load error
Reading/decompressing the firmware has failed.
---
1. Re-install the firmware. (Page 227)
1. Replace the Main Board. (Page 107)
200D
System interrupt
watchdog time-out error
A system failure such as CPU failure, or defective
cash has occurred.
---
Replace the Main Board. (Page 107)
3000 AC shut-off
The AC power has been shut off due to a power
failure, unplugged, Power Supply Board failure, or
Main Board failure or the like.
Is the Power cable properly connected?
1. Replace the Power Supply Board. (Page 109)
2. Replace the Main Board. (Page 107)
Dxxy
Service call for FW
debugging
This error is intended to be used in the product
development stage. It is supposed to not occur with
marketed product, but may occur due to an
unexpected cause such as external noises.
Turn the power off and back on. Does the printer
recover from the error? (No repair work is needed
unless the error occurs again.)
1. Re-install the firmware. (Page 227)
2. Replace the Main Board. (Page 107)
Code Error Name Cause Check Item Remedy