EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Disassembly & Assembly Disassembly Procedure 255
4.2.6.2 PF MOTOR ASSY.
1. Remove the L Side Cover Assy. See Section 4.2.3.5 on page 224.
2. Remove the three screws that secure the PF ENC COVER B. See Figure 4-82.
Three C.B.P. M3 x 8 screws
3. Release the three tabs that secure the PF ENC COVER B and remove it. See
Figure 4-82.
4. Disconnect the connector of the PF Encoder Sensor from the BOARD ASSY.,
SUB; C. See Figure 4-83.
5. Remove the two screws that secure the PF Encoder Mounting Plate and remove it.
See Figure 4-83.
Two C.P.S.(S-P2) M3 x 8 screws
Figure 4-82. Removing the PF ENC COVER B
Figure 4-83. Removing the PF Encoder Mounting Plate
C A U T I O N
When performing the next step, be careful not to deform or damage
the SCALE, PF. See Figure 4-83.
C.B.P. M3x8
Tabs
Left Side of the Printer
PF ENC COVER B
Connector
PF Encoder Mounting Plate
Guide Pins
C.P.S.(S-P2) 3x8