MINI-LINK BAS 9-4
Technical Description EN/LZB 111 0542 P2B
Name Category Severity Description
aal1BufOverflow Comm Minor Sent when buffer-overflow condition is detected.
aal1Starvation Comm Minor Sent when buffer-underflow condition is detected.
atControlChannel Eq Major No communication with modem processor.
atHwFailure Eq Major General hw failure on an AT is detected.
boardMismatch Eq Minor It is sent when the insertion of a circuit board that
does not match the configured data for the slot has
been detected. An alarm ceasing report, alarm
severity cleared, will be sent when matching
configuration data is set for the slot, when the
configuration data is cleared for the slot.
boardRemovedAlarm Eq Major The removal of a matching board from a slot has
been detected or the contact towards the board
has been lost. An alarm ceasing report, alarm
severity cleared, will be sent when a board is
inserted in the slot, or when the management
status of the slot is set to unmanaged or when the
ICS channel towards the board is re-established
again.
boardUnrecognized Eq Minor It is sent when the insertion of a circuit board in a
slot has been detected, but the board ID is not
recognisable, or not valid for this system. An alarm
ceasing report, alarm severity cleared, will be sent
when the board is removed.
bufferOverflow QoS Warning It is sent when a buffer overflows for a while.
bufferUnderflow QoS Warning It is sent when a buffer underflows for a while.
cellbusFailure Comm Major It is sent when a Cellbus has a defect that is longer
than 2.5+/-0.5 sec, cellbus clock missing.
communicationError Eq Major It is sent when a slot is automatically unmanaged,
the board is restarted unprovoked too many times.
disk_full Proc Minor The filesystem on a disk in the CP is almost full.
downLoadLmFailed Eq Major It is sent when the downloading of a new Load
Module (LM) from CP to a DP fails.
dpSoftwareFailure Proc Critical It is sent if the DP software fails. Internal exception
occurs in an ET driver.
ethernetLossOfCarrier Eq Minor It is sent if Ethernet port detects loss of carrier.
fanFailure Eq Major It is sent when a fan failure has been detected in
the subrack. This could be based on detection of
over-temperature in the subrack. An alarm ceasing
report, alarm severity cleared, will be sent when an
indication that the fan is back in operation has been
detected.
hardwareFailure Eq Critical It is sent when a hardware failure occurs on a
board. It is sent if the board fails the self-test.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ericsson MINI-LINK BAS and is the answer not in the manual?

Ericsson MINI-LINK BAS Specifications

General IconGeneral
BrandEricsson
ModelMINI-LINK BAS
CategoryWireless Access Point
LanguageEnglish

Related product manuals