2.3 Configuration Limits
MINI-LINK BAS components have the following configuration
limits:
EM can support to 10 CPs.
1 CP can control up to 128 ATs and support up to 30 SNs.
1 RN supports up to 64 ATs.
1 AT supports up to 4 Ethernet SUs or CE SUs.
2.4 System Interfaces
The system includes several primary physical interfaces.
2.4.1 Intra-System Interfaces
ET155 ATM
155 Mbps, IR, SONET STS-3c (Bellcore GR-253-CORE)/ S1.1
SDH STM-1 (ITU-T G.957)
Full duplex
Single mode optical interfaces
Radio Interface
Channel spacing: 28 MHz
Air capacity: 37.5 Mbps gross bit rate, full duplex using C-QPSK
modulation scheme
Frequency bands:
ETSI 26 GHz
LMDS A 28GHz
LMDS B 31 GHz
Note: The formal Type Approved certification has been obtained
for the given frequencies.
There are also other frequencies that have been
introduced, apply to the local Business Manager for more
information.
Duplex distance:
1008 GHz for ETSI