MINI-LINK BAS 9-12
Technical Description EN/LZB 111 0542 P2B
9.4.1 Signals Monitoring
The RF signal is measured for monitoring of antenna alignment, path
acceptance by means of check the actual RF levels, alarm generation,
RF monitoring, long time RF measurement to discover slow
degradation in system gain.
Acronym Description
PRx min Minimum received power
PRx max Maximum received power
PRx average Average received power
PTx min Minimum output power
PTx max Maximum output power
PTx average Average output power
9.5 Unit Replacement
Replacement of a faulty unit, outdoor or indoor, is done on site.
When an indoor or an ODU has been replaced, the EM automatically
provides the unit set up without any other operation by the
maintenance staff.
The new unit must be of the same type of the replaced one, of course.