30
The slowest logging interval the iMiniPlus can log is every 18 hours.
Start new log trip
The only way to start an iMiniPlus is by using the START button. With other products it is possible to have
a timed or date start as well as a switch start.
You can also program a delay into the starting process of up to 4 hours 15 minutes. This will show
immediately after the Start button is pressed within the iMiniPlus LCD with the words “IN DELAY”. See
section
Starting and using the iMiniPlus
.
Finish log trip
There are several ways to cease a logging trip or period.
You can program the iMiniPlus to log until all the memory is used up (8048 readings) or you may wish to
log only 100 readings for instance.
Alternatively, you can select a certain number of days at which the iMiniPlus will stop logging. For instance
you may only want to record the temperature for a discrete period like a few days, after which you are not
interested in any further data recording.
At each time the iMiniPlus will stop logging and “STOPPED” will be displayed on the LCD
Continuous logging
If you are intending to place the iMiniPlus in an environment that you want to record temperatures 24/7
(for example, laboratory refrigerator), you can select the iMiniPlus to log continuously. This means that the
iMiniPlus will log until the memory it filled up at which time it will start overwriting the first logged data with
the latest.
Users must be careful to routinely download data from the iMiniPlus otherwise data may be lost. Careful
selection of the logging interval is required in this case.
It is possible to download at any time while the iMiniPlus is logging, without changing the program settings
.
Enable stop button in this logger(s)
The iMiniPlus Stop button can be activated through programming by simply ticking the appropriate box. See
section
Stopping the iMiniPlus.
Summary and Upload Program into iMiniPlus
Once you have completed the programming, you will be given an opportunity to review all the conditions in
the Summary tab before you upload into the iMiniPlus. If you are not happy with them select the <BACK
button to return to the appropriate sections and amend.
Check that program settings are what you want.
MP D range MP Dry Ice