Managing Trace Files from the OTDR Test Application
MAX-700 183
OTDR Trace File Compatibility
ToolBox
5.5
ToolBox
6.5 or
earlier
ToolBox
6.7 to
6.20
ToolBox
6.21 or
later
FTB-100
2.5 or
earlier
FTB-100
2.6 or 2.7
FTB-100
2.8 or later/
FTB-150
FTB-200
FTB-200 v2
FTB-1
AXS-100
MAX-700
File generated with...
FTB-100 2.6 or
2.7
--- --- X X X X X
FTB-100 2.8 or
later/
FTB-150
FTB-200
FTB-200 v2
FTB-1
AXS-100
MAX-700
--- --- Conv
e,f
XConv
a,d,
f
Conv
a,d,f
X
a. Should be saved in or converted to FTB-100 (.ftb100) format.
b. Should be reanalyzed to view the events table.
c. Data should be saved in FTB-300 (.ftb300) format and reanalyzed to view the events table.
d. Triple-wavelength trace files are not compatible.
e. Should be converted to ToolBox 6.7-6.20 format.
f. Should be converted with ToolBox 6.21 or later.
Software used to open the file...