Technical Specifications
340 MAX-700
GENERAL SPECIFICATIONS
Size (H x W x D)
190 mm x 252 mm x 66 mm (7
1
/
2 in x 9
15
/
16 in x 2
5
/
8 in)
Weight (with battery) 2.2 kg (4.7 lb)
Temperature Operating
Storage
0 °C to 50 °C (32 °F to 122 °F)
–40 °C to 70 °C (–40 °F to 158 °F)
a
Relative humidity 0 % to 95 % non-condensing
VISUAL FAULT LOCATOR (VFL)
(OPTIONAL)
Laser, 650 nm ±10 nm
CW
Typical P
out
in 62.5/125 μm: 3 dBm (2 mW)
ACCESSORIES
FP4S 400x fiber inspection probe GP-2016 10 foot RJ-45 LAN cable
FP4D 200x/400x fiber inspection probe GP-2028 Computer security cable kit
GP-10-086 Rigid carrying case GP-2137 USB-to-RS-232 converter
GP-10-072 Semi-rigid carrying case GP-2138 DC car adapter/inverter
GP-302 USB mouse GP-2144 USB 16G micro-drive
GP-1002 Headset GP-2155 Carry-on size backpack
b
GP-1008 VFL adapter (2.5 mm to 1.25 mm) GP-2158 Utility glove
GP-2001 USB keyboard
PM-1 BUILT-IN POWER METER SPECIFICATIONS
c
Calibrated wavelengths (nm) 850, 1300, 1310, 1490, 1550, 1625, 1650
Power range (dBm) 26 to —64 (GeX)
Uncertainty (%)
d
±5 % ± 0.4 nW (GeX)
Display resolution (dB)
GeX 0.01 = max to —54 dBm
0.1 = —50 dBm to —60 dBm
1 = —60 dBm to min
Automatic offset nulling range
e
Max power to —40 dBm for GeX
Tone detection (Hz) 270/1000/2000
LASER SAFETY
21 CFR 1040.10 AND IEC 60825-1:2007
CLASS 1M WITHOUT VFL OPTION
CLASS 3R WITH VFL OPTION
Notes
a. –20 °C to 60 °C (–4 °F to 140 °F) with the battery pack.
b. The selected model may change without notice.
c. At 23 ºC ± 1 ºC, 1550 nm and FC connector. With modules in idle mode. Battery operated.
d. Up to 5 dBm.
e. For ±0.05 dB, from 18 ºC to 28 ºC.