7. Attach the PSUs directly to the DIN rail:
Figure 251: V300HT-8T-2X DIN Rail Mount with dual XN-ACPWR-60W-HT-DIN PSUs
Install a V300-8P-2T-W Model in a Single or Dual Rack Mount
You need the following tools and materials to install a V300-8P-2T-W model to a rack mount:
ESD-preventive wrist strap
M4 #2 Phillips screwdriver (magnetic screwdriver recommended)
Typical installation for the V300-8P-2T-W model include wall or table installations, in addition to VESA
mounting. In order to rack-mount this model, an accessory mountin kit is required.
To install the V300-8P-2T-W model in a single or dual rack mount kit:
1. Remove all contents of the single rack mount kit (XN-1S-RKMT-V300) or dual rack mount kit
(XN-2S-RKMT-V300).
2. Attach the short mounting brackets (included) to the sides of the port extender using the four
screws (included) for each bracket.
Figure 252: Single Rack Mounting
Figure 253: Dual Rack Mounting
3. Align the holes in the brackets with the rack post holes.
Install a V300-8P-2T-W Model in a Single or Dual Rack
Mount Installing Expansion Modules
312 ExtremeSwitching Hardware Installation Guide