A952 54 532310 - Rev.A
1 BASIC Programming
BASIC Programming Default
C
SIMPLY CONNECT
Non-modifiable. This symbol indicates that Simply
Connect is available.
1
dF
DEFAULT configuration
Displayed if the board is configured with the factory
settings (default).
Y = the board is configured with the default settings
no = at least one value has been modified compared
to the default settings
If you wish to reload all the default settings, select Y
and exit from programming
Y
t
TYPE OF APPLICATION (see 1 - 7)
1 = shoe 1
2 = shoe 2
3 = articulated
1
S
9
SPRING ACTION
1 = closing spring
2 = opening by spring
1
PG
PUSH AND GO
0 = disabled
1 = enabled in STANDARD mode (an initial manual push
commands motorised opening)
2= enabled in “POWER ASSIST” mode (reduces the
resistance when opening the door to make it easier to
operate by hand).
L
Do not enable POWER ASSIST if the spring
is configured to open.
For the POWER ASSIST function to work
correctly, a new SETUP has to be carried
out each time the spring is adjusted.
In the two-leaf configuration, for the
POWER ASSIST function to work correctly,
POWER ASSIST has to be enabled on both
operators (primary and secondary).
0
PA
PAUSE TIME
Adjusts the time the door remains open after a com-
mand, before automatic reclosing
Adjustable from 0 to 30 s
2
PP
PAUSE TIME PUSH AND GO
Adjusts the time the door remains open after a PUSH
AND GO command, before automatic reclosing
Adjustable from 0 to 30 s
2
Pn
NIGHT PAUSE TIME
Adjusts the time the door remains open after a com-
mand in NIGHT mode, before automatic reclosing
Adjustable from 0 to 90 s
10
CS
CLOSING SPEED
Adjustable from 1 (minimum) to 10 (MAX)
3
C
9
BASIC Programming Default
OS
OPENING SPEED
Adjustable from
1 (minimum) to 10 (MAX)
10
dS
PARTIAL SAFETY STOP
Defines the detection area of the safety in opening.
Do not enable this function if users are children, elderly,
disabled or persons that are not steady on their feet.
no = obstacle detection active over the entire opening
stroke.
Y = obstacle detection NOT active in proximity to the
opening stop
NO
L
Enabling this function requires the SETUP procedure
to be run with the detection device connected: the
activation of the device during opening determines
the point at which obstacle detection will be disabled
during normal operation.
bu
BUS 2easy DEVICE REGISTRATION
see the relative section
no
St
EXIT PROGRAMMING
Exit from the programming function deciding whether
or not to save the changes
Y = save
no = do not save
After exit, the display shows automation status:
00 CLOSED
01 OPENING
02 OPENED
03 PAUSE
04 NIGHT PAUSE
05 CLOSING
06 EMERGENCY ACTIVE
07 MANUAL
08 NIGHT
11 STOP
13 ERROR