A952 63 532310 - Rev.A
1 2 3 4
ON
1 2 3 4
ON
A
B
A
B
1 2 3 4
ON
1 2 3 4
ON
48
1 2 3 4
ON
1 2 3 4
ON
A
B
1 2 3 4
ON
1 2 3 4
ON
49
(26) - COM
(24) OUT2
Test
(25) +24 V
(14) IN5
Opening safety
(13) IN4
Closing safety
(26) - COM
(24) OUT2
Test
(10 / 11) IN1 / IN2
Open
(25) +24 V
(14) IN5
Opening safety
(13) IN4
Closing safety
A
*
B
XPB ON
XPB SCAN / XPB SCAN 3D
violet
green
yellow
white
brown
pink
red
blue
grey
green
yellow
white
brown
pink
red
blue
10.3 SAFETY SENSORS XPB ON , XPB SCAN , XPB SCAN 3D
Below is an example of a pair of sensors (XPB ON = 48 , XPB SCAN/XPB SCAN 3D ( 49) connected in a
PRIMARY/SECONDARY configuration, used as closing (A) and opening (B) safety devices.
Sensor A is connected to input I4 (configured by default as a closing safety device with an NC and Test enabled
contact).
Sensor B is connected to input I5 (configured by default as an opening safety device with an NC and Test
enabled contact).
Output OUT2 (configured by default as Test) is used to monitor the sensors.
DIP switch 1 of each sensor defines the side on which it is mounted:
ON = opening side
OFF = closing side
*
only for XPB SCAN 3D