A952 86 532310 - Rev.A
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
700 800 900 1000 1100 1200 1300 1400
1500
64 Pa
36 km/h
51 Pa
32 km/h
18 Pa
19 km/h
26 Pa
23 km/h
34 Pa
26 km/h
42 Pa
29 km/h
 13 Maximum wind for spring closing
Conditions for calculating the maximum wind pressure:
- Calculation valid for all installation configurations and arms
- Automation not powered with spring movement set to maximum preload, not in the direction of the wind
- The most unfavourable kinematic transmission ratio (leaf opening angle 45°)
- Wind direction always perpendicular to the architrave, in opposition to the closing direction
leaf width
leaf height

Table of Contents