16.3 AUTOMATION STATUS CHECK
The current status of the automation can be checked
on the board or via the KP EVO.
ON THE BOARD
The display of the A952, if you are not in programming
mode, displays the code that indicates the status of
the automation.
ON THE KP EVO
Go to the Programming/Installation/Door Status
menu. The display shows information regarding the
status of the automation.
10 Automation status
00 CLOSED
01 OPENING
02 OPENED
03 PAUSE
04 NIGHT PAUSE
05 CLOSING
06 EMERG. ACTIVE
07 MANUAL
08 NIGHT
11 STOP
13 ERROR
L0 waiting for SETUP to start
L1 SETUP phase 1: stop search
L2 SETUP phase 2: stop search
16.4 OTHER BOARD DATA
Go to the Programming/Installation/Other Board Data
menu of the KP EVO. The display provides information
on the following parameters:
- V MAIN : input voltage to the E952CL board (Volts)
- V ACC : output voltage for accessories (Volts)
- POS : position of the rotating shaft (degrees)
- I MOT : current drawn by motor (Amperes)
16.5 FIRMWARE VERSIONS
ON THE BOARD
When switched on, the display of the A952 shows the
version of the E952CL board firmware for 4 seconds
before displaying the automation status.
ON THE KP EVO
Go to the Info menu of the KP EVO to view the firm-
ware versions of the bootloader, the E952CL board
and the KP EVO.
16.6 ERRORS AND WARNINGS
Alerts provide information regarding the status or
current phase of the automation and errors that do
not prevent it from operating.
Errors are malfunctions that prevent the automation
from working. They are indicated by a steady red LED
on the E952CL board and by automation status 13 that
appears on the board’s display.
After every minute in which an error persists and for a
maximum of 20 consecutive times, the A952 will per-
form a RESET to attempt to restore normal operation so
as not to require any action if the condition that caused
the error was temporary. If the error persists, remove
the cause in order to restore normal operation and
carry out a RESET (alternatively, select and then dese-
lect manual mode).
Every warning and error is indicated by a code that
can be displayed on the board of via the external
functions selectors
ON THE BOARD
Whilst the A952 is displaying the status of the auto-
mation, press the
pp and qq buttons simultaneously:
Er appears on the display followed by any error and
warning codes.
If there is at least one active error, automation status
13 is shown the board’s display and the red LED on the
E952CL board is lit.
ON THE KP EVO
Warnings:
If there is at least one warning, the icon appears on
the home screen. Go to the Warnings menu to view
the list of active alerts.
Errors:
The error code appears on the home page. Go to the Er-
rors menu for information regarding the current error.
ON LK EVO , KS EVO
See the relative sections.