7. CONFIGURABLE OUTPUTS
All the available outputs (OUT1OUT5) can be mod-
ified in programming according to their function and
type of contact.
A brief description of each function is given below.
DISABLED No associated function.
GONG The output is activated and deactivated at
1-second intervals when the safety devices are in use.
ERROR The output is activated if there is an error.
BATTERY OPERATION The output is activated when
operating with the battery.
EMERGENCY ACTIVE The output is activated when an
EMERGENCY is triggered.
TEST The output commands a Test (FAIL SAFE) on the
inputs that are configured as safety devices on which
the option of running a test before movement has
been enabled.
DOOR NOT CLOSED The output remains active until
the door is closed.
DOOR OPENED The output remains active as long as the
door is open.
DOOR OPENING The output remains active as long as the
door is opening.
COURTESY LIGHT The output is activated, for a pro-
grammable length of time, when the door is opened
in NIGHT mode.
INTRUSION ACTIVE The output is activated when
an intrusion is in progress (i.e. when an unexpected
movement of the door from its closed position is
detected).
CLOSING SAFETY ACTIVE The output is activated
when a closing safety device is active.
SAFETIES ACTIVE The output is activated when a
closing or opening safety device is active.
SIMPLY CONNECT The output is activated when Simply
Connect programming is running.
PEOPLE IN NUMBER The output is activated when
the maximum number of people set for the room is
reached (Safe Flow function).
EXTERNAL RED TRAFFIC LIGHT Controls the red light
outside the room to regulate the flow of people to one
person at a time (Safe Flow function).
EXTERNAL GREEN TRAFFIC LIGHT Controls the green light
outside the room to regulate the flow of people to one
person at a time (Safe Flow function).
INTERNAL RED TRAFFIC LIGHT Controls the red light
inside the room to regulate the flow of people to one
person at a time (Safe Flow function).
INTERNAL GREEN TRAFFIC LIGHT Controls the green light
inside the room to regulate the flow of people to one
person at a time (Safe Flow function).
LOW BATTERY The output is activated when the charge
level of the battery is too low for movements to be
carried out.