9. COMMISSIONING
9.1 CLASSIFICATION DIN 186501
Fill out the label 46 based on the table:
 3 Classification DIN 18650-1
digit 1 digit 2 digit 3 digit 4 digit 5 digit 6 digit 7 digit 8
1 3 1 0, 1, 2, 3 1, 2, 3 0, 1, 2, 3, 4 0, 1, 2, 3, 4 4
Digit Meaning Value Description
1 Type of drive 1 Sliding door drive
2 Drive durability 3 1,000,000 test cycles at 4000 cycles/day
3 Type of door leaf 1 Swing leaf
4 Suitability for use as a fire door
0 Not suitable for use as a fire door
1 Suitable for use as a smoke control door only
2 Suitable for use as a fire resisting door
3 Suitable for use as a fire door (smoke control and fire resisting)
5 Drive safety devices
1 Force limitation
2 Connection for external safety systems
3 LOW ENERGY
6
Special requirements for drives /
functions / hitches
0 No special requirements
1 In emergency exits with a break-out system
2 In emergency exits without a break-out system
3 For self-closing fire doors with a break-out system
4 For self-closing fire doors without a break-out system
7
Automatic door safety -
construction / installation
0 No safety device
1 With sufficiently dimensioned safety distances
2 With protection to prevent fingers being crushed, shorn off or drawn in
3 With integrated break-out unit
4 With safety sensors
8 Ambient temperature 4 Ambient temperature range specified by manufacturer