A952 64 532310 - Rev.A
1 2 3 4 5 6
7 8 9
10 11
1 2 3 4 5 6
7 8 9
10 11
50
51
COM
+24 V
COM
NO
- COM
+24 V
COM
NC
10.4 LOCK
L
If the door is used as an escape route, the lock should
not be used.
If the lock needs to be powered in order to be released,
connect it as indicated in 50.
If the lock needs to be switched off in order to be
released, connect it as indicated in 51.
If you power the accessories from the board, the power
consumption of the lock and the other accessories
should not exceed 1.2 A 24V
"
.
In advanced programming on the:
- define the operating mode of the lock (parameter
EL).
- set the opening delay of the door to allow the
lock to be opened, particularly motorised ones
(parameter Et).
- if necessary, enable the reverse stroke to facilitate
the release of the lock (parameter rS).
10.5 SIMPLY CONNECT
The Simply Connect CLOUD platform allows remote
communication with the automation.
Simply Connect requires an accessory FAAC connec-
tivity module.
Insert the module into the dedicated plug-in con-
nectors and
install the "Simply Connect PRO” App.
L
When programming is taking place via Simply Connect,
programming from the board/KP EVO is inhibited.