Electrics / system in general
B030 - position sensor reading
E
Testing
900 > 23/3001
15.2.2001
9000 000058
E
a
1/1
Capitel Docu-No.
Index
Date Version
Page
B030 - position sensor reading
PM-Picturemodule
Text-module
Note:
Ignition "ON".
Text-module
Text-module
Text-module
Note:
Checking EPC box A005 - Chapter 9000 Index E
Adjustment Chapter 9000 Index F
Pin Function
1 Earth
2 Signal
3 + supply
PMTAB_Picture
Note:
Voltage measurement using adapter cable
(DIY)
Made from: 3-core adapter cable
(H 205.860.100.020)
Connect adapter cable directly to component
B030.
Test Pin Target value Condition Possible cause of fault
Supply 3
9.5 +/- 7% VDC
Supply and earth come
from
Earth 1 A005 (EPC box)
Signal 2 approx.
2.5 VDC
Lift assembly lowered
approx.
6.8 VDC
Lift assembly raised
approx.
7.1 VDC
Mech. stop
Earth 1
Measuring points on A005 - EPC box Pin
Earth 20
Signal 7
+ supply 39

Table of Contents