FENDT FAVORIT 900 - B046 - sensor, air-conditioning 1 (in air current)

FENDT FAVORIT 900
1245 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Farmer 400
Fav 700
Fav 900
Electrics / General system
B046 - sensor, air-conditioning 1 (in air current)
E
Testing
02.08.2001
9000 000142
E
a
1/1
Capitel Docu-No.
Index
Date Version
Page
B046 - sensor, air-conditioning 1 (in air current)
PM-Picturemodule
Text-module
Note:
All readings +/- 10%
Text-module
Note:
Chapter 5500 Reg. A - Air-conditioning / General system, operation
Chapter 5570 Reg. E - Electrical check on air-conditioning
PMTAB_Picture
Remove roof cover from cab, then unscrew plastic
cover.
B046 = Sensor, air-conditioning 2 (NTC 1).
Regulates cooling air when
air-conditioning is on.
Note:
NTC =
N egative T emperature C oefficient
in other words, the sensor resistance
decreases with increasing ambient
temperature.
Test Pin Target value Condition Remark
Resistance 1 (white) approx. 10
kOhm
At 20°C ambient tempe-
rature
Sensor (NTC) resistance
decreases with increasing
ambient temperature
2 (white)