5. Testing parts
5-3
Festo P.BE-CB-COMP-EN en 1102d
5.1 The test procedure
During the automatic inspection of workpieces, a reliable
grading of the parts to be tested must be achieved with
respect to orientation and quality (e.g. dimensions specified
have been observed).
The following functions can only be carried out via the PLC
interface:
– Selection of the parts type
– Counter function or test with external sensor
– Monitoring of the buffer zone with switch delay .
Further information can be found in Chapter 3.6.
S Ev aluate the reliability of the Teach data in the test mode
(Chapter 5.2), before you begin with the automatic
inspection of workpieces.
S Protect the Teach data against undesired modification:
– through control panel protection (see Chapter 3.6.8)
– with the CheckKon software:
[Window] [System parameters] Z System Z Operating
modes ... z Teach button lock = On.