Mounting Proceed as follows:
1. Insert the separating seal for the pressure zone
separation.
2. If not alread y provided, mount the following for pressure
zones 2 ... 8: an appropriate pneumatic supply unit for
each pressure zone (see section 5.3.6)
3. MP A-S valve terminal with multi-pin plug connection:
A lengthened version of the interlinking board is required
for bridging the pneumatic supply plate. In the sub-base
which follows the pneumatic supply plate, replace the
short interlinking board with a longer version
(see section 5.3.7 Replacing interlinking boards).
4. Mount the sub-base (see section 5.3.6).
5. Mount the MP A-S valve terminal onto the mounting
surface (see Chapter 2 Fitting, “Mounting onto a wall” or
“Mounting onto an H-rail”).
6. Then install the pneumatic and electrical connections
(see Chapter 3 “Installation, connecting the MPA-S valve
terminal”).