Advanced Menu
The Advanced Menu can be reached
from the Operator Menu by accessing
the Password parameter and setting the
value 60.
Change a Parameter (in the Advanced
Menu)
To change the value of a parameter, pro-
ceed as follows:
• Scroll through the submenus with
the buttons 3 and 4.
• Select the submenu that contains
the parameters to be changed using
the button 2.
• Scroll through the parameters with
the buttons 3 and 4 to find the pa-
rameter to be edited.
• Select the parameter with the button
2.
• Use the buttons 3 and 4 to scroll
through the list of available values
of the parameter.
• Confirm the new value of the param-
eter using the button 2.
• To enable the changes, it is neces-
sary to return to the User Menu; to
exit the parameters and return to
the Advanced Menu press simulta-
neously the buttons 3 and 4, then
find the Exit parameter and confirm
with button 2.
Check/Monitor Function
The Check / Monitor function allows to
check the status of the microswitches
(contact open or closed) and the motors
absorption.
The microswitches status is displayed
by entering the Check / Monitor func-
tion, and scrolling the entries up to
J7: by activating the various switches,
the card will display the status on the
display, showing the number related
with the involved microswitch. The list
of numbers is included in the table (see
section 6.7.3 at page 54).
The motors absorption instead can be
viewed while the machine is in working
condition. To view the values, following
the instruction:
• Access the Advanced Menu by en-
tering the password and confirming
with button 2.
• Press the button 3 or 4 to select the
menu Check/Monitor sub-menu.
• Confirm access to the sub-menu by
pressing 2.
• Press the button 3 or 4 to select the
parameter you want to check during
normal work.
• Press the button 2 to confirm.
• Once confirmed, the display will re-
turn to normal working mode, but in
the second line it will be displayed
the value of the selected parameter.
• By repeatedly pressing button 2 you
can scroll through the single param-
eters.
• To exit form the Check/Monitor
function, turn OFF and ON the ma-
chine.
43