–53–
SYSTEM STATUS
REPORT CODES
(
✱
59Ð
✱
68)
✱
59 EXIT ERROR REPORT CODEÊ (See box on previous page) Ê ÊÊ0ÊÊ
If the system is armed and an Entry/Exit or Interior zone is still open
after the exit delay time has expired, an alarm will sound at the
keypad and external sounder (keypad also displays ÒExit AlarmÓ). If
the system is disarmed before the end of the entry delay that
immediately follows, the alarm sounding will stop and no message
will be sent to the central station. The keypad will display CA
(fixed-word keypads) or CANCELED ALARM (Alpha keypads).
If the system is not disarmed before the end of the entry delay
mentioned above, and an Entry/Exit or Interior zone is still open, an
Òexit alarmÓ message will be sent to the central station if an
Exit Error Report code is selected in this field. The keypad will
display EA (fixed-word keypads) or EXIT ALARM (Alpha keypads),
and the alarm sounding will continue until the system is disarmed (or
timeout occurs).
An ÒExit Alarm Ò condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay, and
an Òexit alarmÓ message will be sent to the central station.
If Contact ID format has been programmed, the message will contain
the zone number and error code 374 (TroubleÐExit Error) to define the
alarm as an Exit Error (rather than E/E or Interior). If 4+2 format is
used, the digit entered in this field will be sent followed by the second
digit of the programmed alarm code for that zone. If 3+1 or 4+1 format
is used, only the digit entered in this field will be sent. This message
will go to the Primary Phone No. Under any of these conditions, no
Restore message will be sent.
If Ò0Ó is entered in this field, no special message will be sent, only the
regular alarm and alarm restore code for the zone.
✱
60 TROUBLE REPORT CODEÊÊ (See box above) ÊÊ0ÊÊ|Ê0ÊÊÊ
This will be sent if a zone goes into trouble.
✱
61 BYPASS REPORT CODEÊ (See box above) ÊÊ0ÊÊ|Ê0ÊÊÊ
This will be sent when a zone is manually bypassed.
✱
62 AC LOSS REPORT CODEÊ Ê ÊÊ0ÊÊ|Ê0ÊÊÊ
See box on previous page. Reports with Partition 1 Subscriber No.
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no AC restore report.
✱
63 LOW BAT REPORT CODE Ê ÊÊ0ÊÊ|ÊÊ0ÊÊ
This will be sent when a low battery condition exists in the systemÕs
standby battery. See box. Reports with Partition 1 Subscriber No.
✱
64 TEST REPORT CODE ÊÊ0ÊÊ|ÊÊ0ÊÊ
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field *51).
See box. Reports with Partition 1 Subscriber No.
✱
65 OPEN REPORT CODE Ê Ê ÊÊ0ÊÊ
This is sent upon disarming of the system. See box. 2nd digit = user
number, if expanded or 4+2 reporting is selected.
✱
66 ARM AWAY/STAY REPORT CODE ÊÊ0ÊÊ|Ê0ÊÊÊ
This option allows for independent programming of AWAY and STAY
reports for each partition. 2nd digit of report is user number if
expanded or 4+2 reporting is selected.
NOTE: OPEN reports are not sent in if the associated closing report
is not enabled.