EasyManua.ls Logo

Fischer Panda 8000x - Failure Code Explanation; Failuretable

Fischer Panda 8000x
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Panda xControl
Seite/Page 180 - Kaptitel/Chapter 11: Panda xControl 10.6.16
Fig. 11.2.1.2-2: Sensor broken english
Fig. 11.2.1.2-3: Sensor broken german
11.2.1.3 Failure code
Fig. 11.2.1.3-1: Failure codeA Failure code is shown if any parameter run out of the
specified range.
see “Failuretable” on page 180
11.2.2 Failuretable
See chapter „Failure“ of your generator manual for help.
Fig. 11.2-1: Failure codes
No.. Description Cause Explication Warning Gen.Stop Info
1 AC-Voltage Voltage to low yes yes n.a.
2 AC-Frequency Frequency to low yes yes n.a.
5 Emergency Emergency button pushed Contact „emergency“ open n.a. yes n.a.
7 Oil pressure Oil pressure to low Failure oil pressure switch n.a. yes n.a.
13 Starter power Starter failure short circuit
Starter defect
yes n.a. n.a.
14 Glow circuit Glow circuit failure short circuit
defect
yes n.a. n.a.
16 Fuel supply Failure fuel supply short circuit
defect
yes n.a. n.a.
17 Stop solenoid - Hold Failure stop solenoid hold coil short circuit yes n.a. n.a.
18 Stop solenoid - Pull Failure stop solenoid pull coil short circuit yes n.a. n.a.
19 Optional DC out Failure optional DC out short circuit yes n.a. n.a.

Table of Contents