Panda_8000i-10000i_System_PVMV-N_eng.R07.1 16.1.15
Manual Vehicle Generator
Panda 8000i PVMV-N 230 V - 50 Hz - 8 kVA - 120 V - 60 Hz - 8 kVA
Panda 10000i PVMV-N 230 V - 50 Hz - 10 kVA
Super silent technology

Table of Contents

Questions and Answers

  • E
    Eric JohnsonAug 15, 2025
    Why is my Fischer Panda 10000i Inverter generator output voltage too low?
    • M
      Michael SteeleAug 15, 2025
      The generator's output voltage might be too low because the PGMi is overloaded. To resolve this, reduce the electrical load by switching off some devices.
  • B
    Brandon RamirezAug 18, 2025
    What to do if my Fischer Panda Inverter motor stops by itself?
    • J
      Jon ThorntonAug 18, 2025
      If the motor stops by itself, it could be due to several reasons. First, check the fuel supply system for a lack of fuel. Second, examine the cooling system for excess heat or a lack of cooling water, indicated on the remote control panel. Check the cooling water system flow, including the water pump, inlet water filter, and coolant flow in the extra heat exchanger. Lastly, check the oil level; if it's low, top it up. If the oil pressure sensor tripped, have the motor's oil pressure repaired by Kubota-Service if necessary.
  • J
    Jesse JohnsonAug 21, 2025
    Why is my Fischer Panda 10000i Inverter producing sooty, black exhaust?
    • S
      Samantha GayAug 22, 2025
      A sooty, black exhaust from your Fischer Panda Inverter can be caused by several factors. It could be due to the generator being overloaded, so check the electrical load and switch off any unnecessary devices. Another cause might be insufficient intake air, in which case you should check and clean the intake air filter. Other potential causes include faulty fuel injector nozzles (replace them), incorrect valve clearance (readjust to the correct value, referring to the Kubota manual), poor fuel quality (use better quality diesel, recommended 2-D Diesel), poor combustion (have the motor serviced by Kubota due to incorrect AFR), or low compression pressure (consult the Kubota motor manual).
  • C
    Corey MorrisAug 26, 2025
    What to do if my Fischer Panda Inverter motor turns over but does not start?
    • W
      watsondavidAug 26, 2025
      If the motor turns over but doesn't start, several issues could be the cause. Start by checking the wire connections and circuitry to the stop solenoid valve. Also, check the fuel filter and pump, cleaning if necessary. Ensure there's enough fuel and check the fuel supply. Verify the glow plugs are working correctly and check the heating time. Inspect the fuel system for leaks and bleed any air from it. Replace the fuel filter if it's blocked. If the issue persists, low compression pressure might be the problem; consult the Kubota motor-manual.
  • W
    William HendersonAug 29, 2025
    Why does the speed of my Fischer Panda 10000i motor drop?
    • R
      Regina BallAug 29, 2025
      A drop in the motor speed of your Fischer Panda Inverter can occur due to several reasons: * Too much oil: Drain oil. * Lack of fuel: Check the fuel supply system, including the fuel filter (renew if necessary), fuel pump, and fuel lines (bleed if necessary). * Lack of intake air: Check air intake paths and clean the air filter (and intake muffler if installed). * Generator overloaded: Reduce the electrical load by switching off devices. * Defective generator: The generator must be sent to the manufacturer for repair of damaged bearings or winding. * Damaged engine: Bearing damage should be repaired by Kubota-Service.
  • A
    adamjonesAug 31, 2025
    What to do if my Fischer Panda Inverter motor does not turn over when starting?
    • R
      Roy ClarkSep 1, 2025
      If the motor doesn't turn over when starting, first check if the battery main switch is switched off and turn it on if necessary. Next, verify that the battery voltage is sufficient and that the connection is firm and free of corrosion. Lastly, investigate for a starting current fault by observing the voltage of full batteries, which should fall to a maximum of 11V. If the voltage doesn't drop, the wiring is severed; if it drops further, the battery is discharged.
  • D
    David GibsonSep 4, 2025
    Why does my Fischer Panda 10000i Inverter motor run irregularly?
    • S
      Sharon BuchananSep 4, 2025
      An irregularly running motor in your Fischer Panda Inverter can be due to a faulty centrifugal injector governor, which should be inspected by a Kubota-Service technician. It can also be caused by too much air in the fuel lines, in which case you should bleed the air from the fuel system.
  • V
    Valerie AlvaradoSep 7, 2025
    What to do if my Fischer Panda 10000i Inverter motor does not turn over at the normal speed during the starting process?
    • J
      josephjamesSep 8, 2025
      If the motor does not turn over at the normal speed during starting, check the starter battery voltage to ensure it is sufficient. Also, damaged bearings or a seized piston could be the cause, requiring repairs by Kubota-Service.
  • C
    Clayton MartinezSep 12, 2025
    What should I do if there is cooling water in the combustion chamber of my Fischer Panda 10000i Inverter?
    • B
      Brandon ThompsonSep 12, 2025
      If there's cooling water in the combustion chamber: 1. Turn the generator "OFF" at the control panel. 2. Remove the glow plug. 3. Rotate the motor by hand carefully. 4. Check if there is water in the oil and change both oil and filter if necessary. 5. Determine the cause for excess water in the combustion chamber, which may be a defective air vent in the cooling water system. Check, clean, or replace the air vent if faulty.

Summary

General Instructions and Regulations

Safety First!

General safety symbols and critical warnings for safe operation.

Safety Instructions - Safety First!

Detailed safety precautions for operation, maintenance, and installation.

The Panda Generator Overview

Panda iControl2 Panel Operation

Describes the Panda iControl2 panel, its buttons, and display functions.

Installation Instructions

Personnel Requirements & Hazards

Specifies who should perform installation and lists associated installation hazards.

Electrical and Fuel Connections

Details electrical connections and fuel system installation procedures.

Generator DC System Installation

Instructions for connecting the generator's DC system, including starter batteries.

Generator Operation Instructions

Personnel Requirements & Operation Hazards

Who should operate the generator and associated hazards.

General Operating Instructions

Covers operation at low temperatures, light load, and load management.

Maintenance Instructions

Oil Level Check and Refilling

Procedure for checking and refilling the engine oil level.

Engine Oil and Filter Replacement

Step-by-step guide for replacing engine oil and the oil filter.

Starter Battery Verification

Instructions for checking the starter battery and performing battery checks.

Air Filter and Coolant System Ventilation

Instructions for replacing the air filter and ventilating the coolant circuit.

Injection Nozzle and Glow Plug Replacement

Steps for replacing injection nozzles and glow plugs.

Generator Failure

Personnel Requirements & Hazard Notes

Who should handle generator failures and associated hazards.

Generator Overloading

Explains how overloading affects the generator and how to prevent it.

Starting Problems

Troubleshooting common starting problems with the generator.

Troubleshooting Table

A table listing common generator faults and their potential solutions.

Safety Instructions for the Panda iControl2

Safety Instructions

General safety instructions and warnings specific to the Panda iControl2 controller and generator.

General Operation

Generator Operation Modes

Details various operating modes like stand-by, start-up, override, operation, and autostart.

Installation

Personnel Requirements & Hazard Warnings

Specifies who should perform installation and lists associated installation hazards.

Warnings and Error Messages

Faults and Bus Errors

Explains error messages, their causes, faults, and bus communication errors.

Annex

Inverter Panda PMGi 8000; PMGi 10000

Safety Instructions & Type Plate

Safety precautions and identification of the PMGi inverter's type plate.

Fischer Panda 10000i Specifications

General IconGeneral
Model10000i
TypeInverter Generator
AC Voltage230 V
Frequency50 Hz
Fuel TypeDiesel
CoolingWater-cooled
Rated Power10 kW
Max Power11 kW
AC Output Power (Continuous)10, 000W
Output Power10, 000W
Input Voltage12V DC
ProtectionOverload, Short Circuit

Related product manuals