Manual Flamcomat G4 + Flamcomat Starter G4
We reserve the right to change designs and technical specifications of our products.
11
ENG
4.9 Noise reduction
Installations should be constructed with noise-reduction measures in mind. Mechanical vibrations of the
assembly (Module framework, pipework) in particular can be dampened by using insulation between contact
surfaces.
4.10 EMERGENCY-STOP / EMERGENCY-OFF
To conform with directive 2006/42/EG an EMERGENCY-STOP facility is to be made available during installation.
Preferably, use a grounded wall socket for the power supply to the unit. The socket must stay accessible. If the
unit is directly connected to the power supply, make sure the power supply line is provided with
- a high-sensitivity dierential switch (30mA) (residual current device RCD)
- a mains isolator switch with a contact gap of at least 3 mm.
When additional security measures with EMERGENCY-OFF devices are required according to the design and
operation of the heat generator, these are to be installed on-site.
4.11 Personal protective equipment (PPE)
PPE must be used when carrying out potentially dangerous work and other activities (e.g. welding), in order to
prevent or minimise the risk of personal injury if other measures cannot be taken. These must comply with the
requirements specified by the main contractor or operator of the operations room or the site in question.
If no requirements are specified, to operate the automat no PPE is required. Minimum requirements are well-
fitting clothing and sturdy, closed and skidproof footwear.
Other services require the protective clothing and equipment necessary for the activity in question (e.g. transport
and assembly: rugged, close-fitting work clothing, foot protectors [safety shoes with toe caps], head protection
[safety helmet], hand protectors [protective gloves]; maintenance, repair and overhaul: rugged, close-fitting work
clothing, foot protectors, hand protectors, eye/ face protector [safety goggles]).
4.12 Exceeding permitted pressure / temperature levels
Equipment used in combination with the expansion automat must guarantee that the permitted operating
temperature and the permitted medium temperature (heat transfer medium) cannot be exceeded. Excess
pressure and temperature may lead to component overload, irreparable damage to components, loss of
function and, as a result, to severe personal injury and damage to property. Regular checks/inspections of these
safeguards must be carried out. Service logs must be kept.