Safety information
2.2 Intended use
M3560-02en Edition 09/2022 17
2.2 Intended use2.2 Intended use
Only use the coupling according to the conditions specified in the service and delivery con-
tract and the technical data in the annex. Deviating operating conditions are considered im-
proper use. The user or operator of the machine or system is solely liable for any resulting
damage.
When using the coupling please specifically observe the following:
• Do not make any modifications to the coupling that go beyond the permissible machining
described in these instructions. This also applies to touch protection facilities.
• Use only original replacement parts from Flender. Flender only accepts liability for ori-
ginal replacement parts from Flender.
Other replacement parts are not tested and approved by Flender. Non-approved re-
placement parts may possibly change the design characteristics of the coupling and thus
impact active and/or passive safety.
Flender will accept no liability or warranty whatsoever for damage occurring as a result
of the use of non-approved replacement parts. The same applies to any accessories that
were not supplied by Flender.
If you have any queries, please contact our customer service organisation (see Service and
support (Page53)).
2.3 Safety information for a coupling when used in potentially
explosive atmospheres2.3 Safety information for a coupling when used in potentially explosive atmospheres
Information
Declaration of conformity
A declaration of conformity required according to the respective Explosion Protection Direct-
ive can be found in chapter Declaration of conformity (Page71)
2.3.1 Marking2.3 Safety information for a coupling when used in potentially explosive atmospheres
You can find a description of the coupling parts in chapter Description (Page21).
A coupling designed in accordance with the Explosion Protection Directive has a marking on
the coupling parts.
The following marking is visible on the outer diameter of a coupling part (e.g. the flanged
sleeve):
Flender GmbH II 2G Ex h IIC T6 ... T5 Gb X
D 46393 Bocholt II 2D Ex h IIIC T85 °C ... 100 °C Db X
ZAPEX <Year of manufacture> I M2 Ex h Mb X