Operation
7.2 Fault – causes and correction
M3560-02en Edition 09/2022 45
7.2.3.2 Correcting the changed alignment7.2 Fault – causes and correction
A changed alignment of the coupling during operation often occurs when the coupled ma-
chines shift compared to one another. A cause of this can be loose foundation bolts.
Procedure
1. Correct the cause for the change in alignment.
2. Carry out a visual inspection of the coupling for damage.
3. Check the locking elements that prevent axial movements and correct these as required.
4. Realign the coupling.