Page #238 background image
Theory of thermography
38
where:
W
λb
Blackbody spectral radiant emittance at wavelength λ.
c
Velocity of light = 3 × 10
8
m/s
h Planck’s constant = 6.6 × 10
-34
Joule sec.
k
Boltzmann’s constant = 1.4 × 10
-23
Joule/K.
T Absolute temperature (K) of a blackbody.
λ Wavelength (μm).
Note The factor 10
-6
is used since spectral emittance in the curves is expressed in
Watt/m
2
, μm.
Planck’s formula, when plotted graphically for various temperatures, produces a family of
curves. Following any particular Planck curve, the spectral emittance is zero at λ = 0,
then increases rapidly to a maximum at a wavelength λ
max
and after passing it ap-
proaches zero again at very long wavelengths. The higher the temperature, the shorter
the wavelength at which maximum occurs.
Figure 38.4 Blackbody spectral radiant emittance according to Planck’s law, plotted for various absolute
temperatures. 1: Spectral radiant emittance (W/cm
2
× 10
3
(μm)); 2: Wavelength (μm)
38.3.2 Wien’s displacement law
By differentiating Planck’s formula with respect to λ, and finding the maximum, we have:
This is Wien’s formula (after Wilhelm Wien, 1864–1928), which expresses mathemati-
cally the common observation that colors vary from red to orange or yellow as the tem-
perature of a thermal radiator increases. The wavelength of the color is the same as the
wavelength calculated for λ
max
. A good approximation of the value of λ
max
for a given
blackbody temperature is obtained by applying the rule-of-thumb 3 000/T μm. Thus, a
very hot star such as Sirius (11 000 K), emitting bluish-white light, radiates with the peak
of spectral radiant emittance occurring within the invisible ultraviolet spectrum, at wave-
length 0.27 μm.
#T559954; r. AP/42311/42335; en-US
224

Table of Contents

Other manuals for FLIR T1020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T1020 and is the answer not in the manual?

FLIR T1020 Specifications

General IconGeneral
Resolution1024 × 768 pixels
Detector TypeUncooled microbolometer
Digital Camera5 MP
Laser PointerYes
Wi-FiYes
Image Frequency30 Hz
Detector Pitch17 µm
Digital Zoom1-8x continuous
Video RecordingYes
Storage MediaSD card
Spectral Range7.5 – 14 µm
Temperature Range-40 °C to +2000 °C (-40 °F to +3632 °F)
Field of View28° x 21°
Display4.3 in LCD touchscreen, 800 × 480 pixels
FocusMotorized and manual
Image ModesThermal, visual, MSX
Operating Temperature-15 °C to +50 °C
Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)
ConnectivityUSB 2.0, HDMI
Image StorageJPEG
Image FormatsJPEG
Thermal Sensitivity<20 mK at 30°C