Introduction and Specifications
Electrical Specifications 1
1-39
5700A Series II AC Current Specifications: 95 % Confidence Level
Absolute Uncertainty
±5 °C from calibration temperature
[1]
Relative Uncertainty
±1 °C
24 Hours 90 Days 180 Days 1 Year 24 Hours 90 Days
Range Resolution
Frequency
(Hz)
± (ppm output + nA)
220 µA
1 nA 10 - 20
20 - 40
40 - 1 k
1k - 5 k
5k - 10 k
550 + 25
280 + 20
100 + 16
400 + 40
1300 + 80
600 + 25
310 + 20
120 + 16
500 + 40
1400 + 80
650 + 25
330 + 20
130 + 16
550 + 40
1500 + 80
700 + 25
350 + 20
140 + 16
600 + 40
1600 + 80
375 + 25
220 + 20
90 + 16
375 + 40
1200 + 80
400 + 25
250 + 20
100 + 16
400 + 40
1200 +80
2.2 mA 10 nA 10 - 20
20 - 40
40 - 1 k
1k - 5 k
5k - 10 k
550 + 40
280 + 35
100 + 35
400 + 400
1300 + 800
600 + 40
310 + 35
120 + 35
500 + 400
1400 + 800
650 + 40
330 + 35
130 + 35
550 + 400
1500 + 800
700 + 40
350 + 35
140 + 35
600 + 400
1600 + 800
375 + 40
220 + 35
090 + 35
375 + 400
1200 + 800
400 + 40
250 + 35
100 + 35
400 + 400
1200 + 800
22 mA 100 nA 10 - 20
20 - 40
40 - 1 k
1k - 5 k
5k - 10 k
550 + 400
280 + 350
100 + 350
400 + 4000
1300 + 8000
600 + 400
310 + 350
120 + 350
500 + 4000
1400 + 8000
650 + 400
330 + 350
130 + 350
550 + 4000
1500 + 8000
700 + 400
350 + 350
140 + 350
600 + 4000
1600 + 8000
375 + 400
220 + 350
090 + 350
375 + 4000
1200 + 8000
400 + 400
250 + 350
100 + 350
400 + 4000
1200 + 8000
± (ppm output + µA)
220 mA
1 µA
10 - 20
20 - 40
40 - 1 k
1k - 5 k
5k - 10 k
550 + 4
280 + 3.5
100 + 3.5
400 + 40
1300 + 80
600 + 4
310 + 3.5
120 + 3.5
500 + 40
1400 + 80
650 + 4
330 + 3.5
130 + 3.5
550 + 40
1500 + 80
700 + 4
350 + 3.5
140 + 3.5
600 + 40
1600 + 80
375 + 4
220 + 3.5
90 + 3.5
375 + 40
1200 + 80
400 + 4
250 + 3.5
100 + 3.5
400 + 40
1200 + 80
2.2 A
10 µA
20 - 1 k
1 k - 5 k
5 k - 10 k
500 + 35
600 + 80
6500 + 160
550 + 35
650 + 80
7500 + 160
600 + 35
700 + 80
8000 + 1600
650 + 35
750 + 80
8500 + 160
500 + 35
550 + 80
6000 + 160
550 + 35
650 + 80
7000 + 160
5725A Amplifier:
11 A
100 µA
40 - 1 k
1 k - 5 k
5 k - 10 k
370 + 170
800 + 380
3000 + 750
400 + 170
850 + 380
3300 + 750
440 + 170
900 + 380
3500 + 750
460 + 170
950 + 380
3600 + 750
300 + 170
700 + 380
2800 + 750
330 + 170
800 + 380
3200 + 750
Note:
Maximum output from the calibrator’s terminals is 2.2 A. Uncertainty specifications for 220 A and 2.2 mA ranges are increased by a
factor of 1.3 plus 2 µA when supplied through 5725A terminals. Specifications are otherwise identical for all output locations.
1. For fields strengths >0.4 V/m but 3 V/m, add 1 % of range.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series and is the answer not in the manual?

Fluke 5700A Series Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity10% to 90% non-condensing
Frequency Range10 Hz to 1 MHz
AccuracyVaries by function and range. See manufacturer's specifications for details.
Output StabilityVaries by function and range. See manufacturer's specifications for details.
Power Requirements50 Hz to 60 Hz