Performance Test Record
Performance Test Record A
A-13
Level Accuracy - 75
Ω
Levelling Head (96040A and 96270A)
Use an AC Measurement Standard, a power meter and power sensors, and a
high performance spectrum analyzer/measuring receiver to make the
measurements shown in Tables A-16 and A-17.
Table A-16. Level Accuracy (75 Ω) Test
Level Frequency Actual Tolerance
+10 dBm
1 kHz ±0.12 dB
20 kHz ±0.12 dB
100 kHz ±0.12 dB
10 MHz ±0.12 dB
100 MHz ±0.12 dB
300 MHz ±0.15 dB
1.4 GHz ±0.25 dB
+7 dBm
1 kHz ±0.12 dB
20 kHz ±0.12 dB
100 kHz ±0.12 dB
10 MHz ±0.12 dB
100 MHz ±0.12 dB
300 MHz ±0.15 dB
1.4 GHz ±0.25 dB
2 GHz ±0.3 dB
-3 dBm
1 kHz ±0.12 dB
20 kHz ±0.12 dB
100 kHz ±0.12 dB
10 MHz ±0.12 dB
100 MHz ±0.12 dB
300 MHz ±0.15 dB
1.4 GHz ±0.25 dB
2 GHz ±0.3 dB