EasyManua.ls Logo

Fluke DSP-4300 - Cable Types Tested

Fluke DSP-4300
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DSP-4000 Series
Users Manual
8-10
Cable Types Tested
Shielded and unshielded twisted pair (STP and UTP) LAN cabling:
TIA Category 3, 4, 5, 5E, and 6 100
ISO/IEC Class C and D 100 and 120
Foil-screened twisted pair cables (ScTP):
TIA Category 3, 4, 5, 5E, and 6 100
ISO/IEC Class C and D 100 and 120
Shielded twisted pair cables (STP): 150
(IBM Type 1, 6, and 9; IBM interface adapter required).
Coaxial cables (connect with the RJ45 to BNC adapter):
Thicknet (10BASE5; adapter required)
Thinnet (10BASE2)
RG-58, RG-58 foam, RG-59, RG-59 foam, RG-8, RG-8A/U, and RG-62.
Note
For availability of additional adapters that allow testing to other
performance standards, different cabling types, or fiber optic
cabling, contact Fluke Networks.

Table of Contents

Related product manuals