Maintenance and Specifications
Specifications
8
8-21
Power
Main unit and remote: NiMH battery pack, 7.2 V, 3500 mAh
Typical NiMH battery life: 8 to 10 hours
Charge time: 4 hours
AC adapter/charger, USA version: Linear power supply; 108 V ac to 132 V ac
input; 15 V dc, 1 A output
AC adapter/charger, international version: Switching power supply; 90 V ac to
264 V ac input; 15 V dc; 1 A output
Memory backup power in main unit: Lithium battery
Typical life of lithium battery: 5 years
Environmental Requirements
Operating temperature: 32 °F to 113 °F (0 °C to 45 °C)
Storage temperature: -4 °F to +140 °F (-20 °C to +60 °C)
Pollution degree: 2
Altitude: 6562 ft (2000 m)
Avoid use outside the operating boundaries shown in Figure 8-3.
Electromagnetic Compatibility
Emissions EN61326-1, Class A.
Immunity EN61326-1
Note: Exposure to a 3 V/m Rf field, in the range of 107 MHz 148 MHz may
cause a maximum noise floor offset of +.62 dB above the calculated specification
of 1.5 dB.