DTX Series CableAnalyzer
Technical Reference Handbook
7-52
To use the power meter in MONITOR mode:
Note
If you need to save the power reading, use the
power meter function in the SINGLE TEST mode.
1
Clean the tester’s input port, the reference test cord
connectors, and the source connector.
2
Use the reference test cord to connect the source to the
tester's input port, as shown in Figure 7-27.
3
Turn on the source.
4
Turn the rotary switch to MONITOR; then select Power
Meter.
5
Press P.
6
Select the appropriate wavelength; then press P. The
power meter in MONITOR mode runs continuously
until you press
I.
Figure 7-28 describes the power meter screens for SINGLE
TEST and MONITOR modes.
amd126f.eps
Figure 7-27. Connections for Monitoring Optical Power (MONITOR mode)