3.2.6 Manual Controller Problems
A magnet is located
underneath the
rectangular protrusion.
Its function is to
distin
g
uish between the
Manual and the Auto
modes
3.2.6.1
One or more of
the Manual
Controller buttons
do not respond
Y
ES
NO
Does the
button
respond?
Electrical equipment stored for a
long period of time starts to
oxidize. Few activations of the
Manual Controller button are
required to remove the oxidation
from it.
The activations remove the
oxidation and the button will
function normally. This
phenomenon is prevented when
the Robomower is in use because
the Manual Controller is constantly
under voltage, which delays the
oxidation
p
rocess.
Press the button, which
does not respond several
times continuously (up
to 30 times)
NO
Y
ES
Is it a new
Robomower or is
it the first
operation after an
extended stora
g
e
period (winter)?
Check the suspected
faulty button (Choose
Buttons’ under the ‘Safety
test’ menu) and replace
the Manual Controller if
found fault
y
.
The Manual Controller
button is OK, continue
operation
3.2.6.2
Is the M.
Controller in its
place (flushed
with the Top
Co
v
e
r
su
rf
ace)
?
Y
ES
NO
Replace the M. Controller with a
g
ood
one and view the display to see if it
changes to Auto menu when it
flushed with the Top Cover
Make sure that prior to
inserting the Manual
Controller to its place,
the cord is stored well
underneath.
Manual Controller
display does not
change to ‘Zone A’ /
‘Dock zone’ when
p
lacin
g
it in its
p
lace
The Manual
Controller is
faulty -
Replace
Remove the Top
cover – confirm
there is a ma
g
net
inside the cover
Is it
changed?
NO
Y
ES
24