EasyManua.ls Logo

Fronius IG Plus 5.0-1 - Page 158

Fronius IG Plus 5.0-1
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
148
Fronius IG
Plus 6.0-1
(continued)
Frequency trip limit accuracy 0.05 Hz
Frequency clearing times 0.016 - 300 s
Total harmonic distortion < 3 %
Power factor 1
* assured by electrical design of the inverter.
General data
Maximum efficiency 96.2 %
CEC efficiency at 208 V 95.5 %
at 240 V 96.0 %
at 277 V 96.0 %
Consumption in standby (night) < 1 W
Consumption during operation 15 W
Cooling controlled forced ventilation
Protection type NEMA 3R
Unit dimensions (w x h x d) 36.46 x 17.09 x 9.61 in.
926 x 434 x 244 mm
Inverter weight 57 lbs.
26 kg
Wiring compartment weight 26 lbs.
12 kg
Shipping dimensions (w x h x d) 42.72 x 20.28 x 14.02 in.
1085 x 515 x 356 mm
Shipping weight 90 lbs.
41 kg
Admissible ambient temperature -4 °F - +122 °F
(with 95% rel. humidity) -20 °C - +50 °C
Admissible storage temperature -4 °F - +140 °F
(with 95% rel. humidity) -20 °C - +60 °C
Protection devices
Ground fault protection internal GFDI (Ground Fault Detector/Interruptor)
Islanding protection internal
DC reverse polarity protection internal diode
Over temperature output power derating / active cooling

Table of Contents

Related product manuals