EasyManua.ls Logo

Fronius IG Plus 5.0-1 - Connecting Solar Module Strings

Fronius IG Plus 5.0-1
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Connecting
Solar Module
Strings
Wire Cross
Section of
Solar Module
Strings
(continued)
1
1
2
1
CAUTION! Danger of damaging the inverter by overload.
Connect a maximum of 20 A to one single DC input terminal.
NOTE Only use water tight conduit fittings and conduits.
Conduit fittings and conduits are not part of the scope of delivery
for the inverter.
1
3
3
1/2 in.
2
4
5
4
6
4
2
1
*
Wire for solar module grounding
Conduit
WARNING! An electric shock can be fatal. Inadequately sized
electrical components can cause serious injuries to persons
and damage to (or loss of) property.
- Use minimum AWG 14 to maximum AWG 6, min. 167°F
(75°C), copper wire for all DC wiring connections to the
Fronius IG Plus. Voltage drop and other considerations may
dictate larger size wires be used.
- Use only solid or stranded wire. Do not use fine stranded
wire
Tightening torque:
stranded wires ................1.25 ft. lb.
solid wires ......................0.81 ft. lb.

Table of Contents