Status codes and remedy
Display Status codes are displayed on the user interface of the inverter in the "System"
"Event Log" menu or in the user menu under "Notifications" or in Fronius Sol-
ar.web*.
* with corresponding configuration, see chapter Fronius Solar.web on page
15.
Status codes
1030 – WSD Open (operating LED: flashes red)
A device that is connected in the WSD chain has interrupted the sig-
nal line (e.g., surge protection device) or the bypass installed ex works
as standard has been removed and no trigger device has been in-
stalled.
If the SPD surge protection device has tripped, the inverter must be
repaired by an authorized specialist.
Install the bypass installed ex works as standard or a trigger device.
Turn the WSD (wired shutdown) switch to position 1 (WSD master).
WARNING!
Danger from work that is not carried out properly.
This can result in severe personal injury and damage to property.
The installation and connection of an SPD surge protection device may only
be carried out by Fronius-trained service personnel in accordance with the
technical specifications.
Observe safety rules.
Cause:
Remedy:
OR:
OR:
1173 – ArcContinuousFault (operating LED: flashes red)
An electric arc has been identified on the PV system, and the maxim-
um number of automatic connections within 24 hours has been
reached.
Keep the sensor pressed on the inverter for 3 seconds (max. 6
seconds).
On the user interface of the inverter, in the menu field "System"
"Event Log", confirm the status "1173 – ArcContinuousFault".
On the user interface of the inverter, in the user menu "Messages",
confirm the status "1173 – ArcContinuousFault".
CAUTION!
Danger from damaged components of the PV system
This can result in severe personal injury/damage to property.
Before the status "1173 – ArcContinuousFault" is confirmed, the entire PV
system affected must be checked for any possible damage.
Damaged components must be repaired by qualified specialists.
Cause:
Remedy:
OR:
OR:
1191 – AfciDataTransfer (operating LED: flashes yellow)
An electric arc has been identified on the PV system.
No action required.
Cause:
Remedy: