85
EN
Care, maintenance and disposal
General The cleaning device generally needs no maintenance. However, to keep the cleaning de-
vice in good working condition for years to come, several points on care and maintenance
must be observed.
Before each start-
up
- Check fill level in parting agent container and top up if necessary
- Check fill level in parting agent spatter tray and empty if necessary
- Check cleaning cutter for wear and replace if necessary
- Empty the cleaning device spatter tray
- If fitted, empty the wire cutter tray
- Carry out a general visual inspection of the cleaning device and make sure that any
damage is repaired immediately (before start-up)
Daily
NOTE!
Only use solvent-free cleaning products on the cleaning device.
- Remove parting agent deposits and dirt from device
Weekly
NOTE!
Only use solvent-free cleaning products on the parting agent container.
- Check the parting agent container for soiling and clean if necessary
- Blow through the suction filter in the parting agent container using compressed air
from the inside outwards through the suction hose (see "Starting up the parting agent
nebuliser")
Every 6 months Open the device and check the pneumatic valves for:
- leaks
- the secure seating of all screws
- the secure seating of all screw joints on the pneumatic valves
If necessary Open the device and
- clean the inside of the device using dry reduced compressed air
- lightly oil the lifting device cylinder guides
Disposal Dispose of in accordance with applicable national and local regulations.