Loading...
A list appears with the following selection options:
The individual selection options are explained in greater detail below:
Setting the "Blue LED" indicator
Time (minutes) that must be allowed to pass before the blue "battery cooled" in-
dicator comes on to indicate that a battery has cooled down sufficiently. The
time from the end of charging is used as the setting.
A temperature value can be set here in conjunction with the "Temperature-con-
trolled charging" option. The blue "battery cooled" indicator will light up to signal
a sufficiently-cooled battery once the temperature drops below this value.
External start/stop
The following settings are available when external start/stop is selected:
Button
-
The function of the "OK/STOP" key can be simulated using an external but-
ton.
Normal
-
Start ON
Charging starts when an external switch is closed and a battery is detected,
or when the charging plug is connected by closing the auxiliary contacts and
a battery is detected.
-
Start OFF
Charging starts when a battery is connected.
-
Stop ON
Charging is interrupted when an external switch is opened,
or when the charging plug is disconnected by opening the auxiliary contacts.
-
Stop OFF
Opening of an external switch or the auxiliary contacts is ignored.
46

Table of Contents

Other manuals for Fronius Selectiva 3.0